HowTo configure Nortel Secure Router 2330 SIP Gateway with sipX
From SIPfoundry sipXecs IP PBX, The Open Source SIP PBX for Linux - Calivia
Nortel Secure Router 2330
The Nortel Secure Router 2330 provides IPv4/IPv6 routing, survivable SIP-PSTN gateway, WAN connectivity and security services in a cost-effective modular platform.
It supports a variety of voice interfaces including T1/E1, BRI, FXS, FXO, DID and CAMA.
For more information see Nortel Web site
Nortel SR2330 SIP-PSTN gateway configuration for sipX
Please refer to Nortel SR2330 User Guide on detailed information on how to configure SR2330 SIP-PSTN Gateway feature. The examples below are intended to provide guidance regarding configuration of SR2330 for use with sipX server in specific application. The SR2330 configuration for each installation should match the network connectivity and requirements for that installation.
Configuring connectivity to sipX server
Configure connectivity to sipX server. Assuming FE 0/1 port.
interface ethernet 0/1 ip address 1.1.1.1 255.255.255.0 exit
Configuring SIP server and registrar
Assign SIP domain (must match sipX configuration, eg. test.com).
sip ua sip-server dns:test.com registrar dns:test.com exit
Configuring SIP listen IP address and port
Configure SIP listen or "bind" IP address and port. Assuming FE 0/1 port connected to sipX server.
voice service voip
sip
bind all ipv4:1.1.1.1:5060
exit
exit
Configuring a FXS port to connect an analog phone
Configure a FXS port, 2/1, to connect an analog phone with extension 1000. The SIP password 1234 (need to be same password as configured in sipX for phone number 1000)
voice-port 2/1 signal loop-start no shutdown station number 1000 exit
dial-peer voice pots 1 destination-pattern 1000 forward-digits all port 2/1 authentication 1000 1234 no shutdown register e164 exit
Configuring a T1 port to connect to a PSTN switch
Configure a T1 PRI port, 4/1, to connect to PSTN switch. All calls with prefix 408 are routed to this link. To receive and send calls from the sipX server to SR2330 PSTN trunks, one must add SR2330 as a gateway to the sipX using sipX configuration server web user interface. A dial plan also need to be added to sipx server to route the calls to SR2330 SIP-PSTN gateway trunks.
interface bundle pri1
link pri_t1 4/1 voice
isdn
side USR
switch-type primary-5ess
activate
exit
exit
dial-peer voice pots 10 destination-pattern 408.% port 4/1 no shutdown exit